Validity of an isometric mid-thigh pull dynamometer in male youth athletes
Authors
Till, KevinMorris, Rhys
Stokes, Keith
Trewartha, Grant
Twist, Craig
Dobbin, Nicholas
Hunwicks, Richard
Jones, Ben
Publication Date
2017-11-16
Metadata
Show full item recordAbstract
The purpose of the present study was to investigate the validity of an isometric mid-thigh pull dynamometer against a criterion measure (i.e., 1,000 Hz force platform) for assessing muscle strength in male youth athletes. Twenty-two male adolescent (age 15.3 ± 0.5 years) rugby league players performed four isometric mid-thigh pull efforts (i.e., two on the dynamometer and two on the force platform) separated by 5 minutes rest in a randomised and counterbalanced order. Mean bias, typical error of estimate (TEE) and Pearson correlation coefficient for peak force (PF) and peak force minus body weight (PFBW) from the force platform were validated against peak force from the dynamometer (DynoPF). When compared to PF and PFBW, mean bias (with 90% Confidence limits) for DynoPF was very large (-32.4 [-34.2 to -30.6] %) and moderate (-10.0 [-12.8 to -7.2] %), respectively. The TEE was moderate for both PF (8.1 [6.3 to 11.2] %) and PFBW (8.9 [7.0 to 12.4]). Correlations between DynoPF and PF (r 0.90 [0.79 to 0.95]) and PFBW (r 0.90 [0.80 to 0.95] were nearly perfect. The isometric mid-thigh pull assessed using a dynamometer underestimated PF and PFBW obtained using a criterion force platform. However, strong correlations between the dynamometer and force platform suggest that a dynamometer provides an appropriate alternative to assess isometric mid-thigh pull strength when a force platform is not available. Therefore, practitioners can use an isometric mid-thigh pull dynamometer to assess strength in the field with youth athletes but should be aware that it underestimates peak force.Citation
Till, K., Morris, R., Stokes, K., Trewartha, G., Twist, C., Dobbin, N., Hunwicks, R., & Jones, B. (2017). Validity of an isometric mid-thigh pull dynamometer in male youth athletes. Journal of Strength and Conditioning Research, 32(2), 490-493. http://doi.org/10.1519/JSC.0000000000002324Type
ArticleLanguage
enDescription
This is a non-final version of an article published in final form in Till, K., Morris, R., Stokes, K., Trewartha, G., Twist, C., Dobbin, N., Hunwicks, R., & Jones, B. (2017). Validity of an isometric mid-thigh pull dynamometer in male youth athletes. Journal of Strength and Conditioning Research, 32(2), 490-493. http://doi.org/10.1519/JSC.0000000000002324ISSN
1533-4287ae974a485f413a2113503eed53cd6c53
10.1519/JSC.0000000000002324
Scopus Count
Collections
The following license files are associated with this item:
- Creative Commons
Except where otherwise noted, this item's license is described as http://creativecommons.org/licenses/by-nc-nd/4.0/


