Energy expenditure, metabolic power and high speed activity during linear and multi-directional running

Hdl Handle:
http://hdl.handle.net/10034/620494
Title:
Energy expenditure, metabolic power and high speed activity during linear and multi-directional running
Authors:
Oxendale, Chelsea; Highton, J. M.; Twist, Craig
Abstract:
Objectives: The purpose of the study was to compare measures of energy expenditure derived from indirect calorimetry and micro-technology, as well as high power and high speed activity during linear and multi-directional running. Design: Repeated measures Methods: Twelve university standard team sport players completed a linear and multi-directional running condition. Estimated energy expenditure, as well as time at high speed (> 14.4 km.h-1) and high power (> 20 W.kg-1) were quantified using a 10 Hz micro-technology device and compared with energy expenditure derived from indirect calorimetry. Results: Measured energy expenditure was higher during the multi-directional condition (9.0 ± 2.0 cf. 5.9 ± 1.4 kcal.min-1), whereas estimated energy expenditure was higher during the linear condition (8.7 ± 2.1 cf. 6.5 ± 1.5 kcal.min-1). Whilst measures of energy expenditure were strongly related (r > 0.89, p < 0.001), metabolic power underestimated energy expenditure by 52% (95% LoA: 20-93%) and 34% (95% LoA: 12-59%) during the multi-directional and linear condition, respectively. Time at high power was 41% (95% LoA: 4-92%) greater than time at high speed during the multi-directional condition, whereas time at high power was 5% (95% LoA: -17-9%) lower than time at high speed during the linear condition. Conclusions: Estimated energy expenditure and time at high metabolic power can reflect changes in internal load. However, micro-technology cannot be used to determine the energy cost of intermittent running.
Citation:
Oxendale, C., Highton, J. & Twist, C. (2017-in press). Energy expenditure, metabolic power and high speed activity during linear and multi-directional running. Journal of Science and Medicine in Sport.
Publisher:
Elsevier
Publication Date:
2017
URI:
http://hdl.handle.net/10034/620494
DOI:
10.1016/j.jsams.2017.03.013.
Type:
Article
Language:
en
ISSN:
1440-2440
EISSN:
1878-1861
Appears in Collections:
Sport and Exercise Sciences

Full metadata record

DC FieldValue Language
dc.contributor.authorOxendale, Chelseaen
dc.contributor.authorHighton, J. M.en
dc.contributor.authorTwist, Craigen
dc.date.accessioned2017-05-10T09:30:55Z-
dc.date.available2017-05-10T09:30:55Z-
dc.date.issued2017-
dc.identifier.citationOxendale, C., Highton, J. & Twist, C. (2017-in press). Energy expenditure, metabolic power and high speed activity during linear and multi-directional running. Journal of Science and Medicine in Sport.en
dc.identifier.issn1440-2440en
dc.identifier.doi10.1016/j.jsams.2017.03.013.-
dc.identifier.urihttp://hdl.handle.net/10034/620494-
dc.description.abstractObjectives: The purpose of the study was to compare measures of energy expenditure derived from indirect calorimetry and micro-technology, as well as high power and high speed activity during linear and multi-directional running. Design: Repeated measures Methods: Twelve university standard team sport players completed a linear and multi-directional running condition. Estimated energy expenditure, as well as time at high speed (> 14.4 km.h-1) and high power (> 20 W.kg-1) were quantified using a 10 Hz micro-technology device and compared with energy expenditure derived from indirect calorimetry. Results: Measured energy expenditure was higher during the multi-directional condition (9.0 ± 2.0 cf. 5.9 ± 1.4 kcal.min-1), whereas estimated energy expenditure was higher during the linear condition (8.7 ± 2.1 cf. 6.5 ± 1.5 kcal.min-1). Whilst measures of energy expenditure were strongly related (r > 0.89, p < 0.001), metabolic power underestimated energy expenditure by 52% (95% LoA: 20-93%) and 34% (95% LoA: 12-59%) during the multi-directional and linear condition, respectively. Time at high power was 41% (95% LoA: 4-92%) greater than time at high speed during the multi-directional condition, whereas time at high power was 5% (95% LoA: -17-9%) lower than time at high speed during the linear condition. Conclusions: Estimated energy expenditure and time at high metabolic power can reflect changes in internal load. However, micro-technology cannot be used to determine the energy cost of intermittent running.en
dc.language.isoenen
dc.publisherElsevieren
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectGPSen
dc.subjectteam sportsen
dc.titleEnergy expenditure, metabolic power and high speed activity during linear and multi-directional runningen
dc.typeArticleen
dc.identifier.eissn1878-1861en
dc.date.accepted2017-03-01-
or.grant.openaccessYesen
rioxxterms.funderNAen
rioxxterms.identifier.projectUnfundeden
rioxxterms.versionAMen
rioxxterms.licenseref.startdate2019-12-31en
This item is licensed under a Creative Commons License
Creative Commons
All Items in ChesterRep are protected by copyright, with all rights reserved, unless otherwise indicated.